Secant Cardio IIe Especificações Página 25

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 24
Troubleshooting
22
Type of telephone
CARDIO can communicate with Touch-Tone telephones only.
Central monitoring station
When activating the account:
1. check the “Monitoring” menu in Advance configuration if the monitoring station’s telephone
number has been entered as well as the protocol used and the customer’s code;
2. check also alarm codes in the “Alarm code” menu in Advance configuration.
NOTE: If only one of the above data is not entered correctly, the monitoring station will be unable to
monitor the home
.
CARDIO cannot take the telephone line
1. check if telephone numbers have been entered in the Telephone Configuration menu;
2. if the telephone network seems fine, change CARDIO.
Important noises when using a telephone
These noises could come from two different sources:
from CARDIO’s power supply if it is overloaded;
from a noise running in the Earth ground (green wire):
1. Disconnect the ground wire and check if the noise is still here;
2. if yes, remove loads from CARDIO’s central controller;
3. if not, localize the source of this noise and reconnect the green wire.
Vista de página 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 52 53

Comentários a estes Manuais

Sem comentários